Home › Fluid & Pump › Pump Head

Pump Head Calculator

Enter your system data — head and hydraulic power update instantly.

Formula

H = Hs + hf + hm   |   hf = f · (L/D) · v²/2g   |   hm = ΣK · v²/2g
Hydraulic power: P = ρ · g · Q · H

Typical Friction Factors

Pipe materialf (turbulent, approx.)
Smooth PVC / PE0.015
Commercial steel0.020
Galvanized iron0.025
Old / corroded pipe0.035+

FAQ

What is static head?

The vertical distance the pump must lift the fluid, independent of flow.

Why is my head higher than expected?

Most undersized-pipe problems: velocity losses grow with v², so halving the pipe diameter roughly multiplies friction by 10.